COM-3010PRO
The negative ion measuring instrument for ores

New model sale
COM-3010PROX


  The weak radiation generated from a natural ore or ceramics reacts to the molecule in the air, and an anion is made. A natural ore and ceramics are measured by a sensor, and it converts into the number of anions with the microcomputer of internal organs, and displays. Please use it as management of a product besides the cloth produced commercially using a natural ore and ceramics, bedding, clothing, wall material, and accessories, and a measuring instrument for sales promotion.

 

   Five kinds of measurement modes  
  1. Standard Measurement Mode :   20-second measurement
2. Speed Measurement Mode :  10-second measurement
3. Automatic Measurement Mode :   Exact measured value
4. Moving Average Measurement Mode :  Somewhat exact measured value
5 Investigation Mode :   Investigation of the source of a signal
 
     


Imitation cautions
The imitation photograph which came for repair is here.


To the visitor who purchased the imitation of COM-3010PRO accidentally
Taking imitation as a trade-in, COM-3010PRO sells at an extraordinarily cheap price.
Please ask.




         
    COM-3010PRO . Ore    



       
  ■Mode 1  Standard measurement mode
It measures for 20 seconds. Measured value is calculated to negative ion and a value is displayed on a display for indication.
 
  ■Mode 2  Speed measurement mode
It measures for 10 seconds. Measured value is calculated to negative ion and a value is displayed. 
 
  ■Mode 3  Automatic measurement mode
Measurement for 20 seconds is performed 8 times. Themaximum, the minimum, and average value are calculated and average value is displayed on a display for indication.

 
  ■Mode 4 Moving average measurement mode
The measurement for 20 seconds is repeated 16 times for every second. The number of negative ion averages 16 times of measured value, and displays it on a display for indication. 
 
  ■Mode 5  Investigation mode
The number of signals is counted up.  When the source of a signal is strong, a count becomes early. When the source of a signal is weak, a count changes late
 



Specification

■Display for indication: 4 figure+1 / 2 digital liquid crystal display  ■Beep: A piezo-electric buzzer
■Signal LED: It is LED lighting with a signal. ■×10 LED: It is LED lighting when increasing 10 times.
■Time base range: 0-100,000 pieces/cc ■Detector: GM sensor
■Printer output: It prints to an option printer. ■Low battery : Consumption of a dry cell will display LOBAT.
■Automatic printing: It is automatic printing at the time of the end of measurement. ■Auto-power-off: A power supply is shut off automatically.
■Power supply: Four AA alkaline dry cells ■Case weight: 420g (with no battery)
■Accessories: A leather case, four AA alkaline dry cells, an operation manual. ■Case size:140mm × 77mm × 53mm




Taisho Ike JAPAN



Taisho Ike JAPAN