Ion Counter , Air Leak Detector , Corona Detector , Product development and manufacture

COM SYSTEM ,INC.

COM SYSTEM ,INC.
2-2-53, Hanenaka,
Hamura-city, Tokyo, Japan
TEL:81-42-533-6377
FAX:81-42-533-6378






COM-1010PRO specification


Leak detection display According to the numerousness of the amounts of air leaks, it displays on the digital liquid-crystal-display machine of 0-100.
Sensitivity adjustment According to the numerousness of the amounts of air leaks, it is changed in a range of a maximum of 60 dB. 1-64 steps of digital sensitivity adjustments
Leak detection frequency 40KHz
Leak detection sound output Leak detection sound is outputted to a headset jack. (Monophonic signal output)
Switch Power switch, Sensitivity adjustment switch ▲, A sensitivity adjustment switch.▼
Auto power OFF A power supply is shut off after 30 minutes from operation of a switch.
Battery Loule Bell detection It is a LOBAT display when a dry cell is exhausted.
Power supply Four AA alkaline dry cells, A hour of use is about 30 hours.
Power consumption About 210 mW
Outer diameter size Length 165 mm (35 mm of + sensors) x Width 80 mm x Height 35 mm
Weight 255g (A dry cell is not included)
The amount display of air leaks 【The amount measurement of air leaks】
Measurement distance 0.1m , pressure 0.1MPa , 0.000L/ minute - 1.100L/ minute
Measurement distance 1.0m , pressure 0.3MPa , 0.0L/ minute - 22.9L/ minute
Measurement distance 3.0m , pressure 0.5MPa , 0.0L/ minute - 84.3L/ minute
Measurement distance setup 【The amount measurement of air leaks】 Five kinds 0.1m (The amount measurement mode of very small leaks), 0.5, 1.0, 2.0, 3.0m
Pressure setup 【The amount measurement of air leaks】] Seven kinds 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7MPa
LED level indication setup LED lights up according to the level of an air leak signal. 10, 20, 30, 40, 50, 60, 70, 80, 90 
Accessories Case, The case protective cover made of rubber, Stereo headphone, Phon, Laser pointer, Four AA alkaline dry cells, Operation manual

   
  1. The amount of air leaks is based on the data which measured the ideal air leak,
Please understand that a numerical value may not suit depending on air leak measurement conditions.

 
  2.3.0 m of the amount measurement distance setup of leaks is the distance set up when displaying the quantity which leaks from piping instead of the maximum detecting ability.
If detecting ability has many amounts of leaks, it can be detected even from the distantly distant place.